What hinge should I use with my electrified 9KW, 45HW, and IDH MAX (9KM/45HM)?

Answer

The chart below can be used to guide your choice. It is recommended that you use 24 gage wire for power or double up 28 gage wires.

Wire Count:
9KW Power = 2 wires (54 suffix if power is doubled up, or 66 suffix with 4 unused 28AWG wires)
9KW w/ RQE = 4 wires (56 suffix if power is doubled up, or 66 suffix with 2 unused 28AWG wires)

45HW Power = 2 wires (54 suffix if power is doubled up, or 66 suffix with 4 unused 28AWG wires)
You will need a 2 additional 28AWG wires if the following sensors are called out on your model number: RQE, DS, or LS. Also IDH* is a sensor option that would require 4 additional 28AWG wires)

*IDH = a sensor option for 45HW that adds both RQE and DS.

IDH MAX
Always has 2 power wires and 2 data wires = 56 Suffix (if you double up the power wires) or 66

Applies To

 45HW, 9KW, IDH MAX

Additional Information

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request

Limited Warranty on Information: The documents contained on this website are distributed as is, without warranty of any kind, either express or implied, including but not limited to implied warranties for the document’s quality, performance, merchantability, or fitness for any particular purpose. Neither Stanley Security Solutions, Inc., nor its dealers or distributors shall be liable to the user or any other person or entity with respect to any liability, loss, nor damage caused or alleged to be caused directly or indirectly by this information.